Recent content by Sudalai

  1. Sudalai

    Electrical Can a Transformer Be Converted into a Welder Transformer?

    Hello Mr radio That's ok, well explanation about what do to use it?
  2. Sudalai

    Effective cross-sectional area

    Dear Tom, S.F means stacking factor refer to below link
  3. Sudalai

    Calculating Core Loss on a Toroid Core

    Sorry for the inconvenience, I need 4000 voltage for in our testing purpose but I have single phase variac 240 v so I would like to design step up 230: 4000v I am is a beginner for designing so I am struggling that
  4. Sudalai

    I have some technical questions about a toroidal transformer core

    Yes, this is medium size toroid core Slit coil means The manufacturing of strips wound cores is a specialized process, which requires a high degree of precision. These cores are manufactured from selected coils of CRGO electrical steel to yield closely controlled electro-magnetic characteristics...
  5. Sudalai

    Calculating Core Loss on a Toroid Core

    Hello! I want your help for core losses on how to calculate core loss on a toroid core?
  6. Sudalai

    I have some technical questions about a toroidal transformer core

    I have 150 x 100 x 60 M4 grade toroid core and same grade slit coil, I need to 180 x 100 x 60 in my design purpose.i would like to add OD 20 mm. my suspicion is a slit that can be added should be on the same grade?
  7. Sudalai

    Effective cross-sectional area

    Thanks for your reply this will be helpful to me
  8. Sudalai

    Effective cross-sectional area

    Dear Mr, tom I saw a lot of websites I got these formula OD-ID/2*H OR OD-ID/2*H*S.F, which one is correct
  9. Sudalai

    Effective cross-sectional area

    Hello sirs, How to calculate the cross-section area too toroid core? kindly explain this
Back
Top