Recent content by danielng245

  1. danielng245

    Please help calculate flowrate frm blower to push water down

    This is a picture i took from internet that describes my problem the most It's exactly the same, only without part no.6 ( cover) In no.34, there are 2 holes for air to go inside ( from blower ) and go outside I use 6 chambers(no.24) using paralleled air flow from one blower but I'm guessing...
  2. danielng245

    Please help calculate flowrate frm blower to push water down

    no need for full specs, i mean just to get the flow rate of blower to get the water down at the rate of 1.25 m/s There is already information of : surface area of water = 2,75m*1,8m designated velocity = 1.25 m/s with the temperature of 20 degree Celsius ( room temperature) Pressure of the...
  3. danielng245

    Please help calculate flowrate frm blower to push water down

    sorry, my point is the water is not splashed
  4. danielng245

    Please help calculate flowrate frm blower to push water down

    the blower are not directly facing the surface of water, the chamber is airtight, but there is a hole below the chamber linking it to a bigger pond with same height as the water inside the chamber. simulated already, but we need the precise blower specification for the real one.
  5. danielng245

    Please help calculate flowrate frm blower to push water down

    How to calculate how much flowrate from blower i can push water pool 2,75m*1,8m down by 1,25m in 1 sec? Note : Blower Pressure 0.03 bar - 0.035 bar There is an empty room above the water pool with dimension of 2.75m*1.8m*1.7m This process happen in a closed chamber...